EMC refers to a system or equipment can function well in electromagnetic environment, and meanwhile do not cause electromagnetic interference to other systems or equipments.
All test equipments in AGC EMC lab are produced by international famous manufacturer such as Germany R&S, Switzerland EMTEST, America AR and so on. There are two 3-meter semi-anechoic chambers, three shielded rooms, two electromagnetic interference test system, two electromagnetic anti- interference test system, four wireless communication equipment test system and so on, therefore AGC can provide one-stop EMC test service.
Service Scope:
1. EMC test site rental service
2. EMC, EMS, RF testing and test reports issuance
3. Assist customers to apply and obtain CE, FCC, E/e-Mark, VCCI, CCC and so on certificates
4. EMC rectification service
5. EMC consultation, counseling and training
6. international standards counseling and training
Standards | Scope |
---|---|
EN 61000-4-4, IEC 801-4,IEC 61000-4-4 | Electrical transient bursts immunity |
EN 61000-4-16, IEC 61000-4-16 | DC to 150 kHz continuous conducted interference |
EN 61000-4-6, IEC 61000-4-6 | conducted interference of RF field |
EN 61000-4-2, IEC 61000-4-2 | electrostatic discharge |
EN 61000-4-8, IEC 61000-4-8 | power frequency magnetic field |
EN 61000-4-9, IEC 61000-4-9 | pulsed magnet field |
EN 61000-4-3, IEC 61000-4-3 | pulsed magnet field |
EN 61000-4-5,IEC 61000-4-5 | surge |
EN 61000-4-11, IEC 61000-4-11 | voltage sag, supply interruption and voltage change |
FCC Part 15 | unintentional radioactive source and intentional radioactive source |
FCC Part 18 | ISM |
EN55011,IEC/CISPR11,GB 4824 | ISM |
EN55013,IEC/CISPR13,GB 13837 | AV or broadcast products |
EN55020,IEC/CISPR20,GB 9383 | AV or broadcast products |
EN55014-1,IEC/CISPR14,GB 4343.1 | home appliances |
EN55014-2,GB 4343.2 | home appliances |
EN55015,IEC/CISPR15,GB 17743 | lamps and lanterns |
EN61547,GB/T 18595 | lamps and lanterns |
EN55022,IEC/CISPR22,VCCI V-3,GB 9254 | ITE |
EN55024,IEC/CISPR24,GB/T 17618 | ITE |
EN62040-2 | UPS. the second section: electromagnetic compatibility |
EN61000-6-1,GB/T 17799.1 | products in residential, commercial, and light industrial environment |
EN61000-6-2,GB/T 17799.2 | products in industrial environment |
EN61000-6-3,GB 17799.3 | products in residential, commercial, and light industrial environment |
EN61000-6-4,GB 17799.4 | products in industrial environment |
EN60555-2,EN61000-3-2,GB 17625.1 | harmonic |
EN60555-3,EN61000-3-3,GB 17625.2 | voltage flicker |
Main Test Items
EMI Tests
EMS Tests
•ESD noise immunity
•EFT noise immunity of power port
•EFT noise immunity of signal line or control line
•conductive coupling of power line /transient noise immunity (auto parts)
•conductive coupling of signal line or control line (auto parts)
•surge and lightning shock of signal line or control line
•shell radiated susceptibility, noise immunity of TEM RF filed (auto parts)
•noise immunity of BCI (auto parts)
noise immunity of strip line (auto parts)
•conductive noise immunity of power port
•conductive noise immunity of signal line or control line
•voltage sag and interruption of power port
·ITE | ·lamps and rectifier | ·electronic toys |
·AV and similar equipment | ·power transformer, supply unit and similar equipment | ·UPS |
·home appliances and similar equipment | ·automotive electronics components and parts | ·battery |